MagnaValve Selector Guide for Air Blast Applications |
|
24 Volt dc Models |
Model |
CPN |
|
|
Kg/min capacity* |
Pounds/min capacity* |
Use with Controller |
| 576-24 |
999381 |
|
|
1 |
2 |
FC-24 |
 |
|
|
| 577-24 |
999289 |
|
|
5 |
10 |
FC-24 |
 |
 |
|
| 578-24 |
999290 |
|
|
15 |
30 |
FC-24 |
 |
 |
|
| 579-24 |
999291 |
|
|
50 |
100 |
FC-24 |
 |
 |
|
| 580-24 |
999292 |
|
|
100 |
200 |
FC-24 |
 |
 |
|
| 590-24 |
999293 |
|
|
150 |
300 |
FC-24 |
 |
 |
|
| Note: MagnaValves standard calibration meets aerospace specification AMS 2432 accuracy of ±10%. Calibration to ±3% accuracy available upon request. |
Standard Models 120 Vac |
|
Kg/min capacity |
Pounds/min capacity |
Use with Controller |
577 |
|
|
|
5 |
10 |
FC |
 |
 |
 |
578 |
|
|
|
10 |
20 |
FC |
 |
 |
 |
579 |
|
|
|
50 |
100 |
FC |
 |
 |
 |
| 580 |
|
|
|
100 |
200 |
FC |
 |
 |
 |
| Note: MagnaValves standard calibration meets aerospace specification AMS 2432 accuracy of ±10%. Calibration to ±3% accuracy available upon request. |
On/Off Models |
|
Kg/min capacity |
Pounds/min capacity |
Use with Controller
(no controller required) |
| 178 DC |
999318 |
|
|
15 |
30 |
110 Volt ac or
24 Volt dc |
| 178 AC |
999319 |
| 179 DC |
999320 |
|
|
50 |
100 |
110 Volt ac or
24 Volt dc |
| 179 AC |
999321 |
| 180 DC |
999327 |
|
|
100 |
200 |
110 Volt ac or
24 Volt dc |
| 180 AC |
999328 |
| 190 DC |
999337 |
|
|
150 |
300 |
110 Volt ac or
24 Volt dc |
| 190 AC |
999338 |
| Note: Valve is normally closed, no flow, with no voltage applied. For proper operation the applied voltage tolerance ±10% is required. |
| Application Note AN-179 Proper Installation Technique for MagnaValves and Sensors |
| |
*Depending on shot size: Contact factory for more information
Click here for Earlier Product Information
A reference table of nozzle performance as a function of shot size, air pressure and desired Almen intensity is available to assist your selection.
Maximum flow capacity is affected by shot size. |